1.
International Eye Science ; (12): 847-851, 2020.
Article in Chinese | WPRIM | ID: wpr-820905

ABSTRACT

@#AIM: To observe the clinical efficacy and safety of new EX-PRESS glaucoma drainage device implantation combined with ranibizumab drugs in the treatment of neovascular glaucoma(NVG).<p>METHODS: A total of 78 patients(78 eyes)who were diagnosed with neovascular glaucoma and underwent intravitreal injection of ranibizumab drugs in our hospital from June 2015 to June 2018 were selected. Sixty patients with complete follow-up data were randomly divided in the experimental group(A), 30 patients(30 eyes)underwent EX-PRESS glaucoma drainage device implantation. Postoperative complications were observed early, visual acuity and intraocular pressure were observed at 1wk, 1mo, 3mo, 6mo and 1a, and the success rate of the operation was evaluated at 6mo and 1a. <p>RESULTS:After 1wk, 1, 3mo, 25 eyes, 25 eyes and 23 eyes with BCVA <0.1 in the experimental group, the average intraocular pressure was 16.76±3.21mmHg, 15.63±2.70mmHg and 16.69±3.29mmHg, the control group was 26 eyes, 26 eyes and 25 eyes, the average IOP was 17.31±2.96mmHg, 14.44±2.53mmHg and 16.56±4.14mmHg(all <i>P</i>>0.05); 6mo after operation, 16 eyes and 16 eyes in the 1a test group with BCVA <0.1 were the average IOP 15.49±3.19mmHg, 18.52±4.03mmHg, the control group was 25 eyes and 25 eyes, the average intraocular pressure was 21.96±2.90mmHg, 28.90±4.33mmHg(all <i>P</i><0.05); the experimental group had low intraocular pressure, shallow The number of cases of anterior chamber, anterior chamber hemorrhage, inflammation, choroidal detachment were 0 eyes, 1 eyes, 2 eyes, 1 eyes, 0 eyes, while the control group were 6 eyes, 6 eyes, 5 eyes, 4 eyes, 2 eyes(<i>P</i><0.05); 6mo after operation in the experimental group, the success rate of 1a operation was 83% and 80%, while that in the control group was 60% and 53%, respectively(<i>P</i><0.05).<p>CONCLUSION: EX-PRESS glaucoma drainage implantation combined with ranibizumab drug treatment in the vitreous cavity can effectively reduce the intraocular pressure in patients with neovascular glaucoma and has the advantages of small surgical incision, simple operation, safety, fewer postoperative complications, and high success rate of surgery.

2.
International Eye Science ; (12): 1902-1905, 2018.
Article in Chinese | WPRIM | ID: wpr-688621

ABSTRACT

@#AIM:To explore the effects of EX-PRESS glaucoma drainage device implantation and trabectome on visual acuity, intraocular pressure, central anterior chamber depth(ACD)and postoperative complications in patients with primary open angle glaucoma(POAG)complicated with cataract. <p>METHODS: The clinical data of 64 patients(64 eyes)with POAG complicated with cataract in our hospital from March 2015 to January 2017 were retrospectively analyzed. Among them, 34 patients(34 eyes)were given EX-PRESS glaucoma drainage device implantation and cataract phacoemulsification(the Group A)and another 30 cases(30 eyes)were given trabectome combined with cataract phacoemulsification(the Group B). The visual acuity \〖best corrected visual acuity(BCVA)\〗, intraocular pressure, ACD and the thickness of macular ganglion cell complex(GCC)were compared between the two groups before operation and at 5mo after operation, and the differences of postoperative complications were also recorded between the two groups. <p>RESULTS: At 5mo after operation, the BCVA, intraocular pressure(IOP)was lower than that before operation(<i>t</i> <sub>Group A</sub>=39.359, 21.045; <i>t</i> <sub>Group B</sub>=23.126, 16.863; <i>P</i><0.01), and the Group A was lower than that in the Group B(<i>t</i>=9.452, 2.761; <i>P</i><0.01). There was no significant difference in the ACD level before and after operation between-groups and within-groups(<i>P</i>>0.05). At 5mo after operation, there was no significant difference in the thickness of macular GCC in the Group A compared with that before operation(<i>P</i>>0.05), but the thickness of macular GCC in the Group B was lower than that before operation(<i>t</i>=3.851, <i>P</i><0.05)and was lower than that in the Group A(<i>t</i>=2.269, <i>P</i><0.05). The incidence rate of postoperative complications in the Group A was significantly lower than that in the Group B(<i>χ</i><sup>2</sup>=7.883, <i>P</i><0.05). <p>CONCLUSION: EX-PRESS glaucoma drainage device implantation or trabectome combined with cataract phacoemulsification can receive good treatment effects in treating POAG patients with cataract, but the former one has better effects on reducing IOP and improving visual acuity than those in the latter one. And EX-PRESS glaucoma drainage device implantation can reduce the incidence rate of postoperative complications, and it is also beneficial to the reduction of retinal ganglion cells(RGCs)damage and the disease prognosis.

3.
International Eye Science ; (12): 917-920, 2017.
Article in Chinese | WPRIM | ID: wpr-731310

ABSTRACT

@#AIM: To explore the efficacy of Ex-press glaucoma drainage device on open-angle glaucoma. <p>METHODS: We collected the clinical data of those patients who were diagnosed as open angle glaucoma and had undergone Ex-press glaucoma drainage device implantation or trabeculectomy in the Second Hospital of Anhui Medical University from January 2014 to May 2016. The data of patients was collected and used to make a comparison involving sex, ages, best corrected visual acuity(BCVA), intraocular pressure(IOP), the amount of corneal endothelium cells and complications before and after operations. <p>RESULTS: There was no significantly different(<i>P</i>>0.05)between the Ex-press group and trabeculectomy group on postoperative BCVA at 6mo. Both groups had obvious effects on the drop of IOP after operations(<i>P</i><0.001), but there was no difference between the two groups at any time after operations. Ex-press group had no significant difference at 6mo while it had in the trabeculectomy group about the amount of corneal endothelium cells comparing with preoperative. The incidence rate of overall complications about Ex-press group and trabeculectomy group was 15% and 43% respectively, it had a significant difference between two groups(<i>P</i><0.05). <p>CONCLUSION: The Ex-press glaucoma drainage device had similar efficacy with lower complication rate and smaller influence of corneal endothelium cells comparing with trabeculectomy.

4.
International Eye Science ; (12): 1720-1722, 2017.
Article in Chinese | WPRIM | ID: wpr-641346

ABSTRACT

AIM:To compare the short-term and long-term curative effect between two implantation methods for treating refractory glaucoma.METHODS:A total of 150 patients with refractory glaucoma (150 eyes) were divided into Group A (treated by implantation with Ex-press glaucoma drainage device) and Group B (treated by implantation with Ahmed glaucoma valve) according to different implantation methods.Changes of intraocular pressure and anti-glaucoma drugs at different time points, the success rate of surgery, improvement of visual acuity and complications were compared between the two groups.RESULTS:The intraocular pressure of two groups at 1d, 1wk, 3, 6 and 12mo after surgery was significantly lower than that before surgery (P0.05).CONCLUSION:The effects of implantation with Ex-press glaucoma drainage device are similar to those of implantation with Ahmed glaucoma valve in the treatment of refractory glaucoma.However, the intraocular pressure control effect of the former is better than the latter, and used anti-glaucoma drugs are fewer.

5.
Chinese Journal of Experimental Ophthalmology ; (12): 362-367, 2017.
Article in Chinese | WPRIM | ID: wpr-638203

ABSTRACT

Refractory glaucoma is one of the main blinding diseases in ophthalmology.Glaucoma drainage device implantation has become one of the main methods of refractory glaucoma.It has been widely used in clinic because of its advantages of safety,effectiveness and less complications.After a large number of clinical applications and innovative development of minimally invasive glaucoma surgery,glaucoma drainage device implantation shows its good treatment prospects.In this paper,the structural features of glaucoma external drainage device (Molteno,Schocket,Baerveldt,Human aqueous drainage,Krupin,Ahmed,Joseph,Whites,Optimed drainage device) and microin vasive glaucoma surgery (MIGS) (Ex-PRESS drainage device,Xen Gel Stent,CyPass Micro-Stent,Ab interno trabeculectomy trabectome,Hydrus Schlemm canal scaffold,iStent trabecular micro-bypass stent,SOLX Gold Shunt) were summarized.The drainage device implantations for glaucoma in the role of the refractory glaucoma were reviewed.

6.
Chinese Journal of Experimental Ophthalmology ; (12): 246-249, 2015.
Article in Chinese | WPRIM | ID: wpr-637414

ABSTRACT

Background Ex-PRESS glaucoma drainage device implantations have been clinically applied worldwide.In China,50 type and 200 type of Ex-PRESS glaucoma drainage devices are used for different types of open angle glaucoma.However,whether the clinical outcomes are similar between 50 type and 200 type of Ex-PRESS glaucoma drainage devices are not elucidated.Objective This study was to compare the therapeutic efficacy and security of Ex-PRESS implantation between PS0 type and P200 type of Ex-PRESS glaucoma drainage devices for open angle glaucoma Methods A randomized,parallel-group trial was designed,and written informed consent was obtained from each patient prior to entering in the cohort.Eighty eyes of 69 patients with various types of open angle glaucoma were included from March 2012 to April 2013 in Wuhan General Hospital of Guangzhou Military Command.The patients were randomized into 2 groups according to randomized digital table.The P50 type Ex-PRESS glaucoma drainage device was implanted in 40 eyes of 35 patients in the P50 group,and P200 type was implanted in 40 eyes of 34 patients in the patients of the P200 group.The disease composition,best corrected visual acuity (BCVA) recovery time,theoretical hospitalization days,lowing intraocular pressure (IOP) range and postoperative complications were compared between the two groups.Results The average lowing-IOP ranges of the P50 type group and P200 type group were (21.19±11.22) and (24.35±12.27) mmHg,respectively,with an insignificant difference between them (t =-1.201,P>0.05).The theoretical hospitalization days and BCVA recovery time in the of P50 type group were (3.65±0.92) days and (2.85±0.95)days,and those in the P200 type group were (4.90±0.81) days and (3.40± 0.96) days,showing significant decreases in the P50 type group (t =-6.444,P<0.01 ;t =-2.584,P< 0.05).The incidence of postoperative complications were 6.06% and 25.00% in P50 type group and P200 type group,respectively,with a significant difference between the two groups (.x2 =9.800,P<0.05).Conclusions Although P50 and P200 Ex-PRESS implantation provide a similar effect in lowing IOP,P50 type Ex-PRESS implantation can restore BCVA more rapidly and lessen complications in comparison with P200 type Ex-PRESS implantation in the early postoperative stage.

7.
Modern Clinical Nursing ; (6): 49-51, 2013.
Article in Chinese | WPRIM | ID: wpr-438356

ABSTRACT

Objective To investigate the key points in the care of patients with open angle glaucoma undergoing EX-PRESS drainage device implantation during perioperative period.Method Eighteen patients with open angle glaucoma underwent EX-PRESS glaucoma drainage device implantation and received individualized nursing care during perioperative period.Results Drainage device implantation was successfully performed in 18 patients.The mean operation time was(30.0±5.0)mins,ranged 25 to 45 mins.The postoperative intraocular pressure was stable.Conclusions EX-PRESS glaucoma drainage device implantation is an innovative and effective strategy in the treatment of open angle glaucoma.Comprehensive nursing during perioperative period is important to ensure the clinical efficacy.